• Autoclave Sterilizer Suppliers in India
  • Autoclave Sterilizer
  • Autoclave-Sterilizer2

Description

Autoclave Sterilizer manufactured by us is apt for sterilization of medical consumables, hospital accessories, surgical equipments name a few. Sterilization happens at 121 degree centigrade with steam. Due to steam circulation bacteria killed within the chamber of the equipments. Internal parts are made from high quality stainless steel 304/316 grade materials for regulatory requirements. We provide installation qualification, operation qualification and design qualification of the equipment as per GMP requirements. Our range consist capacity ranging from 30 liters to 10000 liters. Jacket of double walled and triple walled can be offered as per individual process requirements.

Types of Autoclave Sterilizer

  • Hospital Autoclave
  • Medical Autoclave
  • Laboratory Autoclave
  • Industrial Autoclave
  • Steam Sterilizer
  • Horizontal Autoclave
  • Rectangular Autoclave

Autoclave Sterilizer: Ensuring Sterility in Medical and Laboratory Settings

An Autoclave Sterilizer is a vital device in medical, laboratory, and industrial environments, designed to eliminate bacteria, viruses, fungi, and spores through pressurized steam. Adinath International, a leading manufacturer in India, offers autoclave sterilizers that are efficient, reliable, and compliant with international standards.

Design and Construction

Adinath’s autoclave sterilizers feature a robust construction with high-grade stainless steel chambers and exteriors, ensuring durability and resistance to corrosion. The cylindrical design enhances pressure distribution, contributing to effective sterilization. Equipped with user-friendly control panels, these sterilizers allow precise monitoring and adjustment of sterilization parameters.

Operational Mechanism

The autoclave operates by generating saturated steam at temperatures between 121°C and 132°C. Items to be sterilized are placed inside the chamber, and once sealed, the system removes air to create a vacuum. Steam is then introduced, and the combination of high temperature and pressure effectively destroys microorganisms. The process parameters, including temperature, pressure, and time, are meticulously controlled to ensure thorough sterilization.

Salient Features of Autoclave

  • Compact design.
  • Quick temperature achievement.
  • Heavy duty machine made as per 4 kgf/cm²g jacket hydro test pressure.
  • Quick cycle time of 15 – 20 minutes.
  • Radical arm door for proper locking of chamber.
  • Quick vacuum drying.
  • Steam generator provided in industrial models.
  • Solenoid valve for steam to jacket and steam to chamber operation.

Special Features

  • High Efficiency: Utilizes saturated steam to achieve rapid and thorough sterilization.
  • User-Friendly Interface: Digital controls facilitate easy operation and monitoring.
  • Safety Mechanisms: Incorporates pressure release valves and door interlocks to ensure operator safety.
  • Versatility: Suitable for sterilizing a wide range of materials, including medical instruments, laboratory equipment, and pharmaceutical products.
  • Compliance: Meets international standards for sterilization, ensuring reliability and effectiveness.

Applications

Autoclave sterilizers are indispensable in various sectors:

  • Healthcare: Sterilizing surgical instruments, medical devices, and consumables to prevent infections.
  • Laboratories: Decontaminating glassware, media, and equipment used in research and diagnostics.
  • Pharmaceuticals: Ensuring the sterility of products and packaging materials.
  • Food Industry: Sterilizing containers and tools to maintain hygiene standards.

Technical Specifications

While specific models may vary, Adinath’s autoclave sterilizers generally offer:

  • Temperature Range: 121°C to 132°C
  • Pressure Range: 15 to 30 PSI
  • Chamber Volume: Available in various sizes to accommodate different load capacities
  • Control System: Digital PLC-based controls with programmable cycles (optional)
  • Construction Material: Stainless steel chambers and exteriors for durability
  • Safety Features: Automatic pressure control, safety valves, and door interlocks

Maintenance and Safety

Regular maintenance is essential to ensure the longevity and optimal performance of the autoclave sterilizer. Adinath provides comprehensive maintenance guidelines, including routine checks of seals, valves, and control systems. Safety features such as pressure release valves and door interlocks are incorporated to protect operators from potential hazards. Additionally, training is provided to ensure that personnel can operate the equipment safely and effectively.

In a nutshell, Adinath International’s Autoclave Sterilizer offers a reliable and efficient solution for sterilization needs across various sectors. Its robust construction, user-friendly interface, and compliance with international standards make it a valuable asset in maintaining hygiene and safety. When integrated with the Cleaning Machine, it forms a comprehensive system that ensures containers uphold the highest standards of product quality and safety

* Power voltage can be adjusted as per customer’s domestic power voltage requirements.
* Rights of technical improvements & modification reserved.
* Illustrations & dimensions are shown for information purpose only.