Description
Cath Lab Ethylene Oxide Gas Sterilizer is one of the key machines commonly uses in pharmaceutical, textile, healthcare and food industries among others. Adinath International is a leading cath lab hospital EO sterilizer manufacturer in India offering cath lab sterilizer equipped with plethora of features.
What is Cath Lab ETO Sterilizer?
Cath lab ETO sterilizer is an ultra-modern sterilizer that is vastly used in the sterilization of medical, surgical and pharmaceutical products. Ethylene oxide sterilization is an advanced method to sterilize medical devices and other heat sensitive devices. As a pioneering cath lab ethylene oxide supplier in India, we provide advanced hospital EO sterilizer that is not only safe to use but eco-friendly as well. A vast array of delicate devices which are otherwise impossible to sterilize by deploying conventional methods can be seamlessly sterilized using this ultra-modern sterilizer.
Working Principle and Sterilization Process
Let’s take a look at the working principle and several stages involved in the sterilization process. Since, there is no standardized process owing to a vast diversity in exposure periods and gas concentration, the process below is a typical one and must be taken into consideration for reference purposes only.
The machine uses single use EO cartridges of 40, 100 and 170 grams. The chamber is facilitated with a single door and a simple locking system. There is an electronically controlled heating system in place to ensure a uniform heating at 50 degrees centigrade. The machine is designed for optimum durability as it contains venturi of adequate capacity inside a robust cabinet. There are control buttons for heating, gas purging and power supply requirements.
-
Product exposed to warm and humid environment
The product is exposed to a warm and humid environment for about 12 hours. 70 percent RH and 55 A Cº is maintained for a uniform temperature and humidity.
-
Introduction of ETO gas
Now the vacuum is pulled and ETO gas is introduced at this stage. The exposure is for about 4 to 8 hours at the same RH and temperature as before.
-
Removal of ETO gas
Vacuum is continually pulled for the removal of ETO gas and air is introduced into the sterilization chamber to clear out the entire ETO gas. This process lasts for about 8 to 12 hours.
Features of Cath Lab Ethylene Oxide Gas Sterilizer
- Used to sterilize disposable syringes, I.Vs, disposable surgical set, gloves, infusion sets, urine collecting bags, birth control apparatus and plenty of medical devices
- Easy to operate
- Chamber with modular construction
- IQ, OQ and DQ documentation can be provided
- Prevention of micro biological contamination
- Contact parts made of SS 304 and 316
As a leading manufacturer and supplier of cath lab ethylene oxide sterilizer in India, Adinath International offers sterilizers of all sizes, ranging from small ETO sterilizers to room sized sterilizers.
Technical Specification of Hospital EO Sterilizer
| Model | AETOS – 2.6 | AETOS – 4.5 | AETOS – 8 |
| Working Capacity in Cu. Ft. | 2.6 | 4.5 | 8 |
| Working Volume | 70 Liters | 125 Liters | 200 Liters |
| Chamber Size | 12” (W) x 12” (H) x 32”
|
12” (W) x 12” (H) x 54” (D) OR
15” (W) x 15” (H) x 36” (D) |
20” (W) x 18” (H) x 38” (D) OR
16” (W) x 16” (H) x 54” (D) |
| Sterilant Gas | 40 grams cartridge | 100 grams cartridge | 170 grams cartridge |
| Sterilization Cycle | Warm & Cold Cycles are possible | Warm & Cold Cycles are possible | Warm & Cold Cycles are possible |
| Aeration | In-built aeration facility provided | In-built aeration facility provided | In-built aeration facility provided |
| Utility | Compressed Air (100 psig) | Compressed Air (100 psig) | Compressed Air (100 psig) |
| Power Supply | 1 K.W. | 2 K.W. | 2.5 K.W. |
| Power Voltage | 220 volts, Single Phase, 50 Hertz | 220 volts, Single Phase, 50 Hertz | 220 volts, Single Phase, 50 Hertz |
* Power voltage can be adjusted as per customer’s domestic power voltage requirements.
* Rights of technical improvements & modification reserved.
* Illustrations & dimensions are shown for information purpose only.
FAQ of Cath Lab Ethylene Oxide Gas Sterilizer
How does the Cath Lab ETO Sterilizer work?
The sterilization process typically involves three main stages:
- Pre-conditioning: The load is exposed to a warm and humid environment (approx. 55°C and 70% RH) for about 12 hours.
- Gas Exposure: Vacuum is applied, and ETO gas from single-use cartridges (40g, 100g, or 170g) is introduced for 4–8 hours.
- Aeration/Degassing: Residual ETO gas is removed through vacuum and air flushing for 8–12 hours to ensure safety.
The system supports both warm and cold cycles with in-built aeration.
What are the key features and benefits of this sterilizer?
Key features include:
- Easy operation with modular chamber construction
- Contact parts made of high-quality SS 304/316
- Prevention of microbiological contamination
- IQ, OQ, and DQ documentation support
- In-built aeration facility
- Available in multiple capacities (70L, 125L, 200L)
Benefits: Safe for heat-sensitive items, eco-friendly options, reliable for critical medical devices, and suitable for various industry needs.
What sizes/models are available for the Cath Lab ETO Sterilizer?
Adinath offers three standard models:
- AETOS – 2.6: 70 Liters (2.6 Cu. Ft.)
- AETOS – 4.5: 125 Liters (4.5 Cu. Ft.)
- AETOS – 8: 200 Liters (8 Cu. Ft.)
Custom sizes, including room-sized sterilizers, are also available as a leading manufacturer in India.
Is the Cath Lab ETO Sterilizer safe and compliant for hospital use?
Yes. It is designed with safety features like single-use EO cartridges, robust construction, controlled heating, and effective aeration to remove residual gas. It helps prevent microbiological contamination and is ideal for hospital cath labs. Proper documentation (IQ/OQ/DQ) is provided, and the system is built for reliable, repeatable sterilization of critical medical devices.